HS1101

50,000 

  HS1101 Relative humidity sensor  DataSheetBased on a unique capacitive cell, these relative humidity sensors are designed for high volume, cost sensitive applications such as office automation, automotive cabin air control, home appliances, and industrial process control systems. They are also useful in all applications where humidity compensation is needed.FEATURES
– Full interchangeability with no calibration required in standard conditions
– Instantaneous desaturation after long periods in saturation phase
– Compatible with automatized assembly processes, including wave soldering,reflow and water immersion (1)
– High reliability and long term stability
– Patented solid polymer structure
– Suitable for linear voltage or frequency output circuitry
– Fast response time
– Individual marking for compliance to stringent traceability requirements
(1) soldering temperature profiles available on requestMAXIMUM RATINGS (Ta= 25°C unless otherwise noted)

 Ratings
 Symbol
 Value
 Unit
 Operating Temperature
 Ta
 -40 to 100
 °C
 Storage Temperature
 Tstg
 -40 to 125
 °C
 Supply Voltage
 Vs
 10
 Vac
 Humidity Operating Range
 RH
 0 to 100
 % RH
 Soldering @ T = 260°C
 t
 10
 s

CHARACTERISTICS(Ta = 25°C, measurement frequency @ 10kHz unless otherwise noted)
 Characteristics
Symbol
Min.
Typ.
Max.
Unit.
 Humidity measuring range
RH
1
 
99
%
 Supply voltage
Vs
 
5
10
V
 Nominal capacitance @ 55% RH*
C
177
180
183
pF
 Temperature coefficient
Tcc
 
0.04
 
pF/°C
 Averaged Sensitivity from 33% to 75% RH
ΔC/%RH
 
0.34
 
pF/%RH
 Leakage current (Vcc = 5 Volts)
Ix
 
1
 
nA
 Recovery time after 150 hours of condensation
tr
 
10
 
s
 Humidity Hysteresis
 
 
+/-1.5
 
%
 Long term stability
 
 
0.5
 
%RH/yr
 Response time (33 to 76 % RH, still air @ 63%)
Ta
 
5
 
s
 Deviation to typical response curve (10% to 90% RH)
 
 
+/-2
 
% RH